8. SPINDLE PARAMETERS
8.1 Spindle Base Specifications Parameters
II - 225
# Items Details Setting range (Unit)
3029 tapsel Asynchronous
tap gear
selection
Specify whether to use the tap rotation
speed or maximum rotation speed for the
gear that is selected when an
asynchronous tap command is issued.
0: Tap rotation speed
1: Maximum rotation speed
This parameter is valid only when the
M-function synchronous tap cycle enable
parameter (#1272 ext08 bit1) is ON.
0/1
3030
(PR)
(Not used.)
3031
(PR)
smcp_no Drive unit I/F
channel No.
(spindle)
Using a 4-digit number, set the interface
channel No. and which axis in that channel
is to be used when connecting a spindle
drive unit.
High-order two digits : Interface channel
No.
Low-order two digits : Axis No.
When using the conventional fixed layout,
set all axes to "0000".
Set "0000" when using an analog spindle.
0000
0101 to 0107
0201 to 0207
3032
(PR)
(Not used.)
3036 tap_errm Synchronous tap
tolerable error
width
Set the tolerable value for synchronous tap
error width. When "0" is set, synchronous
tap error monitoring will not be executed.
0 to 1000 (µs)
3037
3038
3039
3040
taps21
22
23
24
Synchronous tap
switching spindle
speed 2
Set the spindle rotation speed at which the
step-2 acceleration/deceleration time
constant is to be switched at gear 00, 01,
10, or 11.
0 to 99999 (r/min)
3041
3042
3043
3044
tapt 21
22
23
24
Synchronous tap
switching time
constant 2
Set the time constant to reach synchronous
tap switching spindle rotation speed 2
(#3037 to #3040) at gear 00, 01, 10, or 11.
1 to 5000 (ms)
3045
3046
3047
3048
tapt 31
32
33
34
Synchronous tap
switching time
constant 3
Set the time constant to reach the
maximum rotation speed (#3005 to #3008)
at gear 00, 01, 10, or 11.
1 to 5000 (ms)